To: v i n evacationQgmail.comi
From:
Sent Fri 3/4/2011 4:33:13 AM
Subject Re: GII update
High altitude start could only be verified by an Albuquerque stop, We can't simulate high altitude,
if the apu sounded smooth during start, I'd say it was fixed, but I'm just not comfortable with the
sound during acceleration,
gulfstream is recommending surge valve replacement,. At this point I'm installing parts that we
can't verify are faulty, the surge valve is $7,900
Gulfstrcam is not able to locate the test box for Tstat calibration,. All I have heard today is, this
plane is old, it was called a classic by one Mechanic, and they rarely see GII's at there shop. I'm
glad we are not doing inspection here.
Let's see if they can find a fault with surge valve, I really need Dallas Airmotivc to assist more in
trouble shooting, of course, dallas airmotive told us speed switch, then tstat, all that appears left is
surge valve,. Frustrating, sorry
I'm still at plane now, I'll let you know further finding tonight,
Thx
Larry
Ps; Flight Safety here in Long Beach has just retired their OH sims as did Simuflite, no more exist.
Only GIII's
Sent via BlackBerry by AT&T
From: jeffrey epstein leevacation@gmail.com>
Date: Thu, 3 Mar 2011 20:07:18 -0800
To:
What about altitude
Sorry for all the typos .Sent from my :Phone
On Mar 3, 2011, at 7:59 PM, Ote:
Jeffrey,
Tstat is installed and working, APU is not as smooth as I thought it would sound when
accelerating from 80% to 100%, the part we installed is 41 years old, so that could be an
issue,.We are doing functional checks of the API) Surge Valve, which is the last part of the
air system involved in starting. Surge valve will arrive tomorrow from Savannah at 10:30am is
what I'm being told, just in case we elect to install it,.
I'm fine with APU operation at this point, so we can depart if you like any time tomorrow,.
I will know more around midnight tonight if a problem with surge valve is found„ only takes 1.5
hours to install,. I did not want to delay your departure,.) can always install when we do the
below floor inspection,.if there is an issue found with surge valve,.
The technicians at Long Beach are marginal as far as GIl knowledge, they are folowing the
Tech supports recommendations,.only one guy is approved to run APU, all others are GIV and
up specialist,.
EFTA_R1_00218276
EFTA01837008
Boost pump operation normal.,
changed boost pump Relay for UH side, and two pressure switches,.
I will update you if any findings on surge valve,.let me know if there is a departure time yet?
thank you,
Larry