Epstein Files

EFTA01097435.pdf

dataset_9 pdf 506.5 KB Feb 3, 2026 5 pages
Diesel Generators 10. 3200 Kw I Altematers 5.3500 Kra I Transfer Switches I Fuel Tanks I Trailers I Engine Parts I Alternator Part SDMO I KOHLER I EROADCROWN I HIPCMER I JOHNDEERE I CUMMINS I PERKINS I MITSORSHI I VOLVO I STAMFORD I LEROY SOMER GENERAL POWER GP J100UC3 Engine JOHN Alternator DEERE, 4045HFS83, EPA/CARB Tier 3 LEROY SOMER, LSA44.3S5 100 KW JOHN DEERE GENERATOR 100 KW/125 KVA DIESEL GENERATOR SET. FULLY PACKAGED: • JOHN DEERE Heavy duty diesel engine. 4 stroke. 1800rpm. Turbo. EPA • LEROY SOMER brushless alternator. IP23 protection. Insulation class H • SCHNEIDER. Main line circuit breaker. wired. maximum output rated • EPA Tier 3 compliant engine per U.S. Environmental Protection Agency • Digital auto-stan control panel. CE and UL compliant • Incorporated metallic fuel tank for day use • Auto Stan control feature included for interoperation with ATSIAMF • 12V charging alternator and 12V DC electric starter motor • 12V charged DC starting battery with electrolyte and cables • Dry type air filter. fuel filter and oil filter elements installed • Mechanically welded chassis with vibration isolators • Each unit prototype and individually factory load bank tested • The generator accepts 100% rated load in one step as per NFPA110 and meets 1508528.5 class G-3 for transient response • Compliant with ISO3046. IS08528. BS4999. BS5514. BS500OPT99. AS1359. IEC34. UTE5100. VDE0530 and IS09001:2000 AVAILABLE ACCESSORIES AND OPTIONS: • Steel or Aluminum weather proof. sound attenuated enclosures • UL142 listed. double wall fuel tanks from 50 to 10.000 Gal • UL1008 listed, automatic transfer switches from 50 to 3000 Amp MI compliant heavy duty road trailers from 3000 to 30000 Lbs • Automatic battery chargers. Engine preheaters. Remote annunciators and many more Power ESP Power PRP Voltage kWekVA kWe,kVA Standby Amps Dimensions - Open Weight - Open 480/277 100/ 125 91 / 114 150 460/265 100 / 125 91 / 114 157 Length : 1950mm (77inj 1187kg (2617lbs) Net 440/254 1001 125 91/114 164 Width : 1084mm 143in] 1440kgf3175lbs] Gross 240/139 100 / 125 91 / 114 301 Height : 1350mm [53inj 230/133 1001 125 91/114 314 220/127 100 / 125 91 / 114 328 208/120 1001 125 91 / 144 347 POWER DEFINITION PRP : Prime Power is available for an unlimited number of annual operating hours in variable load applications. in accordance with ISO 8528.1. ESP : The standby power rating is applicable for supplying emergency power in variable load applications in accordance with ISO 8528- 1. Overload is not allowed. TERM OF USE Standard reference conditions ESP/PRP 25 C°/25 C° Air Intim Temp. 1000 m/1000 m m A.S.L. 60 % relative humidity. WEATHER / SOUND PROOF ENCLOSURES Model dB(A)@31t dB(A)@2311 Dimensions -Enclosed Weight - Enclosed Tank Length : 2554mm 110 1in] 1597kg (35211bs] Width : 1150mm [45in1 190 L M129 78 68 Height : 1680mm 166in] 1850kg [4079lbsj 50 Gal GENERAL POWER LIMITED, INC 1350 NW 78 Avenue! Miami, Flonda 33126 EFTA01097435 Diesel Generators 10.320CIKw I AltemMers 5.3500 Ka I TratINSwItche I Fuel Tanks I 'WINN I Engine Parts I AllemaINPAns 0 SDMO KOHtER I ERNIDCROWN I HIPCMER I !CNN DEERE I CUMMNS I PERIONS I MITSUBISHI I VOLVO I STAMFORD I LEROY SOMER GENERAL POWER ENGINE SPECIFICATIONS JOHN DEERE 4045HFS83, Engine model 4-strokes, TURBOCHARGED, AIFVAIR, 4 Cylinders, U.S. EPA / CARS TIER 3 Cylinders-arrangement 4-L Displacement (C.I.) 4.48 Bore (mm) X Stroke (mm) 106 X 127 Compression ratio 19: 1 DATA Speed (RPM) 1800 Pistons speed (mis) 7.62 GENERAL DATA Maximum stand-by power at rated RPM (kW) 118 Frequency regulation (%) +145% BMEP (bar) 15.9 Governor type ELECTRONIC Exhaust gas temperature (°C) 580 EXHAUST SYSTEM Exhaust gas flow (Us) 380 Max. exhaust back pressure (mm CE) 750 Fuel consumption 110% load 31.1 Libr 18.2 gal/lx] Fuel consumption 100% load 28.5 Uhr (7.6 gallhr) FUEL SYSTEM Fuel consumption 75% load 24.8 Libr 16.6 gal/lx) Fuel consumption 50% load 17.7 Libr (4.7 gatlhr) Maximum fuel pump flow 74.7 Uht 119.7 gal/hr) Oil capacity (L) 13 Min. oil pressure (bar) t.05 OIL Max. oil pressure (bar) 3 Oil consumption 100% load (L I) 0.08 Caner oil capacity (L) 12 THERMAL BALANCE Heal rejection to exhaust (kW) 111.15 Radiated heat to ambiant (kW) 14.39 Haat rejection to coolant (kW) 62.3+19.8 AIR INTAKE AIR INTAKE_entree_max% 375 Intake air flow (Us) 136 Emissions PM (g/kWh) 0.25 EMISSIONS Emission CO (g/kW.h) 1.47 Emissions HCNOx (g/kWh) 3.43 Emission HC (g/kW.h) 0.14 GENERAL POWER LIMITED, INC 1350 NW 78 Avenue! Miami, Florida 33126 EFTA01097436 Diesel Generators 10.3200 Kw I Alternators 5.3500 Kra I Transfer Switches I Fuel Tanks I Trailers I Engine Part. I AttematorPasts SDMO r KOHLER I BROALCROYiN I HIPO'KER JOHN EEERE I CUMMINS I PERKINS I MIT9JISSHI I VOLVO I STAMFCR0 I LEROY S0VER GENERAL. POWER ALTERNATOR SPECIFICATIONS Alternator brand LEROY SOMER Alternator LSA44.3S5 Number of phase 3 Power factor (Cos Phi) 0.8 Altitude (m) <1000 Overspeed (rpm) 2250 Number of pole 4 DATA Excitation system / Short Circuit reactance capability Auxiliary Excitation / 300% for 10 seconds Insulation class / Temperature class H/H GENERAL DATA Automatic Voltage Regulator Advanced. R438 Total harmonics TGH/THC <2 Wave form : NEMA=TIF-TGH/THC <50 Wave form : CEI=FHT•TGH/THC <2 Number of bearing Coupling DIRECT Voltage regulation 0 to 100% +/-0.5% Recovery time (Delta U = 20% transitoire) (ms) 500 Continuous Nominal Rating 40°C (kVA) 131 Standby Rating 27°C (kVA) 144 Efficiencies 4/4 load (%) 91 Air flow (cfm) 0.44 Short circuit ratio (Koc) 0.33 Direct axis synchro reactance unsaturated (Xd) (%) 377 Quadra axis synchro reactance unsaturated (Xq) (%) 226 Open circuit time constant (Tdo) (ms) 2555 Direct axis transient reactance saturated a (%) 15 Short circuit transient time constant (ms) 100 (ID OTHER Direct axis subtransient reactance saturated (X"d) (%) 9 Subtransient time constant (T"d) (ms) 10 DATA Ouadra axis subtransient reactance saturated (rq) (%) 10.8 Zero sequence reactance unsaturated (Xo) (%) 0.9 Negative sequence reactance saturated (X2) (%) 9.9 Armature time constant (Ta) (ms) 15 No load excitation current (io) (ms) 0.5 Full load excitation current (ic) (A) 2.1 Full load excitation voltage (uc) (A) 38 Recovery time (Delta U = 20% transitoire) (ms) 500 Motor start (Delta U = 20% perm. or 50% trans.) (ms) 238 Transient dip (4/4 charge) PF : 0.8 AR (%) 17.8 No load losses (kW) 2.72 Heat rejection (kW) 10.25 ___LEROY® GENERAL POWER LIMITED, INC 1350 NW 78 Avenue! Miami, Florida 33126 EFTA01097437 Diesel Generators 10.3200 Kw I /diameters 6.3500 Kra I TransferSwitches I Puerile*, I Trailers I Engine Parts I AlternatorParts SOHO I KOHLER I ERIKLYROWN I HiPasER I =OKVCEERE I CUNHAINS I HERONS I miT9JEKSHI I VOLVO I STAMFORD I LEROY SOMER GENERAL POWER CONTROL PANELS Standard NEXYS NEXYS Specifications : Frequency meter. Ammeter. Voltmeter • • •• • Alarms and faults : Oil pressure, water temperature, Overcrank, Overspeed ( >60 kVA), Min/max alternator, Low S fuel level. Emergency stop Engine parameters : Hours counter, Engine speed, Battery • e voltage, Fuel level, Alr preheating Ostion TELYS2 Specifications : Frequency meter, Ammeter. Voltmeter Alarms and faults : Oil pressure. water temperature. No start- up. Overspeed. Min/max alternator. Minimax battery voltage. Low fuel level, Emergency stop Engine parameters : Hours counter, Oil pressure. Water temperature, Engine speed. Battery voltage. Fuel level Remote monitoring and control ACCESSORIES AND OPTIONS Option Automatic Transfer Switches, 110008 listed: 100 to 4000 AMPS r ASVCi With a Series 300 transfer switch, you get a product backed by ASCO Power Technologies, the industry leader EMERSON •True double-throw operation: single solenoid design is inherently interlocked & prevents contacts from stopping between sources •Easy-to-read flush-mounted control and display panel provides LED indicators for switch position and source availability U •Standard engine exerciser for weekly automatic testing with or without load •UL 1008 listed for Transfer Equipment and CSA C22.2 listed •NFPA 110 for Emergency & Standby Power & the National Electrical (NEC) Articles 700. 701 and 702 O• ion Fuel Tanks, IlL142 listed: 50 to 5000 GAL •UL listed. Secondary containment tank meeting UL 142 tank requirements •NFPA compliant. Designed to comply with the installation standards of NEPA 30 and NFPA 37 LISTED •Emergency pressure relief vents. Meets UL requirements: ensures adequate venting of inner and outer tank under extreme pressure and/or emergency conditions •Electrical stub-up area with removable end channel •Normal vent • Inner tank emergency vent sized to UL 142 specs •Direct reading mechanical fuel gauge • Fuel in basin switch •Satin black paint finish GENERAL POWER LIMITED, INC EFTA01097438 Diesel GiNineff 10.7200 Kw I Allem/don 6.7600 KY. I Tranvia Switches I Fuel TSOM I fl an I EOM Put I MOM&Put S0MO I KOHLER I ERNID0ROWN I HIPOAFR I JOHN DEERE I CUMMINS I PERMS I 1.1ITSUESSHI I VOLVO I STAMECRD I LEROY SOWER GENERAL POWER Weatherproof / Super Silent M129 Enclosure STANDARD FEATURES ▪ 12 gauge electro-zinc powder coated steel for maximum corrosion resistance (Phosphatizing degreasing. Non-chromic passivanon, Osmosis purified rinsing and High durability polyester resin thermosetting powder paint) ■ 29dB(A) Internal-mounted critical silencer and flexible exhaust connector offering maximum component life and operator safety ■ Fade-. scratch-, and corrosion-resistant. Automotive-grade textured finish resulting in advanced corrosion and abrasion protection as well as enhanced edge coverage and color retention ■ Up to 51mm (2in) Acoustic insulation with hydrocarbon sealing film that meets FMVSS 302 flammability classification and repels moisture absorption ■ Interchangeable modular panel construction. Allows complete serviceability or replacement without compromising enclosure design ■ Service access. Multi-personnel doors for easy access to generator set controller. breaker and service points ■ Externally mounted emergency stop button, Single point lifting hook and Tamper proof "securit" viewing control window ■ Cooling air discharge. Weather protective design featuring a vertical air discharge outlet grille. Redirects cooling air up and above enclosure to reduce ambient noise ■ Cooling/combustion air intake with a horizontal air inlet. Sized for maximum cooling airflow ■ Heavy duty Polyamide plastic hinges. Dichromate galvanized bolting and Stainless steel rivets for lifetime longevity ■ Meets and exceeds NFX41002 Salt spray test. NFT30049 UV Performance test, NFT30038 Paint adhesion test and 2000/14EC Low sound directives I C 0 C. E I • POW ER • foI an www.genpowerusa.com Sound level Model Dimensions Weight Tank dB(A)@31t dB(A)@23ft LW A (in) (Ibs) (Gal) GP 1000C3 78 68 N/A 101 x 45 x 66 3521 50 GENERAL POWER LIMITED, INC 1350 NW 78 Avenue / Miami, Florida 33126 EFTA01097439

Entities

0 total entities mentioned

No entities found in this document

Document Metadata

Document ID
3d218aff-57b5-4583-becd-c0aa3f75cf83
Storage Key
dataset_9/EFTA01097435.pdf
Content Hash
bdd3fdfdccc890e02939042254fdd097
Created
Feb 3, 2026