EFTA00652198.pdf
dataset_9 pdf 1.0 MB • Feb 3, 2026 • 14 pages
Gulfstreame
A NNN OVNAMICA COMPANY Part/Model #:
INVOICE
AC Serial No/Tail No.:
7 Char Drive - Westfield. Massachusetts 01085-1493
Mail Remittance To: Overnight Remittance To: Wire Remittance To:
Gu'lantern Aerospace Corporation Gulfstream Aerospace Corporation (Box /I 730349) Gulfstrcam Aerospace Corporation
P.O. Box 730349 do JP Morgan Chase Bank. NA JP Morgan Chase Bank, NA
Dallas, Texas 75373-0349 ATTN: Dallas National Wholesale Lockbox TXI-0029 Chicago, IL 60670
14800 Frye Road Account No. 10-15825
Ft. Won't TX 76155 Fedwire Routing No.
S.W.I.F.T. CHASUS33
ACH Credit Routing No.
Invoice Number: 6916001251
Bill To: HYPERION AIR, INC.
Invoice Date: 41812016
3800 SOUTHERN BLVD
Customer ID: CH200
SUITE 204
P.O. Number:
WEST PALM BEACH, Florida 33406
Repair Station: CRS LECR039G
United States
In Date: 03/05/2016
Out Date: 03/25/2016
Payment Type: Net 30-Open terms
Payment Terms:
Title: HYPERION AIR, INC.
INVOICE SUMMARY FOR WORK ORDER NUMBER: SC13577
Time & Materials Flat Rate Total
Labor USD: 523,752.08 50.00 523,752.08
Pans USD: 510,546.36 50.00 510,546.36
Services USD: 513,050.98 50.00 513.050.98
Detail Subtotal USD: $47,349.42 50.00 S47.349.42
Subtotal USD: $47,349.42
Funds on Deposit USD: 50.00
Total USD: $47,349.42
SCHEDULED MAINTENANCE
FAR PART 91
LARRY VISOSKI 917-868-6145
N2I2JE
RE: PROPOSAL# 7024273 1201 (GAC1015-2422-GIV-)085-R01)
7024691 ROO (GACO216-4691-GIV-)085-120D)
HAPP # 4400-529-21
For detail description of the work complied with see the Work Order Detail report.
Westfield_GAC_Work Unless otherwise indicated, all financial values listed in this document am in US Dollars (USD). Printed: 4(9/2016 4:26:50AM
OrderInvoice.rpt Page 1 of 14 LS MO
EFTA00652198
Bill To: IIYPERION AIR, INC. WO #: SCI3577 Invoice Number: 6916001251
Item: 6 AVIONICS
Team Manager: Charles Helwig Pan/Model #:
Customer Coordinator: Vinny Cicala AC Serial No./Tail No.:
TSN/TSO:
CSN/CSO:
Aircraft Time:
Discrepancy: 6.1 CUSTOMER REPORTS #1 TRANSPONDER LOOSES ATC ALTITUDE READ OUT AFTER ONE HOUR.
Resolution: UNSEATED ATC NO.1 PN: 622-9210-409 SN: 2376. PERFORMED VISUAL INSPECTION OF BOTII THE RACK
AND COMPONENT INSURING NO BENT OR PUSH PINS ARE PRESENT. CLEANED CONTACTS AND
RESEATED ATC NO.1 PN: 622-9210-409 SN: 2376. DISCONNECTED INTERCONNECT FOR ATC NO.1 AND
FOUND MALE PINS S AND T TO BE BENT AND MAKING LIMITED CONTACT WITH FEMALE PINS. WORK
PERFORMED IN ACCORDANCE WITH WIRING DIAGRAM 1159SB41481, GIV AMM 34-02-04 AND GIV WIRING
DIAGRAM 34-55-00. REMOVED ATC NO.2 P/N:622-9210-409 SIN: 1G8hil. UNSECURED ATC RACKS TO
FACILITATE MAINTENANCE. REPLACED ATC NO.1 DISCONNECT CONNECTORS P/N: MS3120F22-55P SN:
UNK AND P/N: M53126F22-55S SN: UNK, RECEIVED P/N: MS3120F22-55P FROM ELECTRO ENTERPRISE
REFERENCE CERTIFICATE OF CONFORMANCE ON PACKSLIP NO: 1779462 DATED 03/14/2016. RECEIVED
P/N:MS3126F22-55S FROM ELECTRO ENTERPRISES REFERENCE CERTIFICATE OF CONFORMANCE WITH
INVOICE NO: 1156087 DATED 05/25/11. PERFORMED WIRING RING OUT CHECK OF ATC NO.1
TRANSPONDER LAW WESTERN COMMANDER WIRING DWG NO:08069197, FOUND GOOD. REINSTALLED
SERVICEABLE ATC NO.1 PN: 622-9210-409 SN: 2376 AND SERVICEABLE ATC NO.2 P/N:622-9210-409 SIN: 1G88/1
AND PERFORMED ATC FUNCTIONAL CHECKS IN ACCORDANCE WITII GIV AMM 34-02-04. NOTED NO
FURTIIER ISSUES AT TIIIS TIME. SEE STEPS FOR DETAILS.
Billing Method Hours Rate Total
Labor USD: Time and Material ST 39.91 ® $132.00 $5,268.12
Parts USD: Time and Material $211.08
Total USD: $5,479.20
Parts:
Ref. No. Pan number Description Quantity Sell price USD Extended USD
6.1 #1 hIS3120F22-55P CONNECTOR 1 $95.68 595.68
6.1 #2 hIS3126F22-55S CONNECTOR 1 $8536 585.36
6.1 #3 686DM3 SLEEVE. BRAIDED 1/2 BLACK 2 53.92 $7.84
EXPANDO
6.1 #4 SPT.50 SPIRAL WRAP TEFLON 1/2" 2 53.30 56.60
NATURAL
6.1 #5 TY25M TYRAP, WHITE 10 50.78 57.80
6.1 #6 TY242M TIE, CABLE; NYLON 8.19 IN.; 0.14 10 50.78 57.80
IN.; 30 LB. TENSILE STRENGTH
For detail description of the work complied with see the Work Order Detail report.
Westfield_GAC_Work Unless otherwise indicated, all financial values listed in this document am in US Dollars (USD). Printed: 49/2016 4:26:50AM
OrderInvoice.rpt Page 2 of 14 LS MO
EFTA00652199
Bill To: HYPERION AIR, INC. WO #: SCI3577 Invoice Number: 6916001251
Step: 6.1.1 Completed APPLIED POWER TO AIRCRAFT. MONITORED ALTITUDE REPORTING ON
BOTH ATC TRANSPONDERS USING ATC 600 TEST SET FOUND GOOD. LET IT
RUN FOR A LONG TIME, WHILE PERFORMING ASCB BUS SWEEP (REF.
SQUAWK 63), FOUND GOOD AT THIS TIME. WORK WAS DONE REFERENCE
GIV A.,M.M. 34-02-04.
Step: 6.1.2 Completed UNSEATED ATC NO.1 PN: 622-9210-409 SN: 2376. PERFORMED VISUAL
INSPECTION OF BOTH RACK AND COMPONENT INSURING NO BENT OR
PUSH PINS ARE PRESENT. CLEANED CONTACTORS AND RESEATED ATC
NO.1 PN: 622-9210-409 SN: 2376. GAINED ACCESS TO AND DISCONNECTED
INTERCONNECT FOR ATC NO.1 AND FOUND MALE PINS S AND T TO BE
BENT AND MAKING LIMITED CONTACT WITH FEMALE PINS.
STRAIGHTENED PINS AND RECONNECTED DISCONNECT. APPLIED POWER
TO AIRCRAFT AND PERFORMED MULTIPLE CHECKS OF ATC SYSTEM
USING IF'R 6000. NOTED NO OCCURENCES OF TRANSPONDER FAILING TO
REPORT ALTITUDE. ALL WORK PERFORMED IN ACCORDANCE WITH GIV
AMM 34-02-04 AND WIRING DIAGRAM I159:O341481.
Step: 6.13 Completed STEP ENTERED IN ERROR
Step: 6.1.4 Completed CONDUCTED RESEARCH TO FIND PART NUMBER FOR ATC TRANSPONDER
INTERCONNECT CANNON PLUG PART NO. PART NUMBER FOR
RECEPTACLE IS MS3120F22-55P PART NUMBER FOR PLUG IS
MS3126F122-555. REFERENCE WESTERN COMMANDER DRAWING NO.
08069197. TITLED NO. 1 TRANSPONDER (MOD) NO REV, DATED 5/12/89. THIS
CONNECTOR CONTAINS VARIOUS 429 DATA INPUTS/OUTPUTS FOR
CONTROL AND TUNING, SUPPRESSION SIGNALS AND TCAS INTERFACE.
AND POWER. ALL WORK PERFORMED IN ACCORDANCE WITH WESTERN
COMMANDER DRAWING NO. 08069197, TITLED NO. I TRANSPONDER (MOD)
NO REV, DATED 5/12189
Step: 6.1.5 Completed REMOVED ATC NO.2 P1N:622-9210-409 S/N: IG/thl. UNSECURED ATC RACKS
TO FASCILITATE MAINTENANCE. REMOVED ATC NO.1 DISCONNECT
CONNECTORS P/N: ItelS3120F22-55P SN: UNK AND P/N: MS3126F22-55S SN: UNK.
INSTALLED NEW CONNECTORS P/N: MS3120F22-55P SN: UNK AND P/N:
MS3126F22-555 SN: UNK. RECEIVED P/N: MS3120F22-55P FROM ELECTRO
ENTERPRISE REFERENCE CERTIFICATE OF CONFORMANCE ON PACKSLIP
NO: 1779462 DATED 03/14/2016. RECEIVED P/N:MS3126F22-55S FROM
ELECTRO ENTERPRISES REFERENCE CERTIFICATE OF CONFORMANCE
WITH INVOICE NO: 1156087 DATED 05/25/11. ALL WORK PERFORMED IN
ACCORDANCE WITH WIRING DIAGRAM 1159SB41481.GIV AMM 34-02-04 AND
GIV WIRING DIAGRAM 34-55-00.
Step: 6.1.6 Completed PERFORMED WIRING RING OUT CHECK OF ATC NO.1 TRANSPONDER IAW
WESTERN COMMANDER WIRING DWG NO:08069197 FOUND GOOD.
Discrepancy: 6.2 CUSTOMER REQUEST TO EXCHANGE THE #2 COM STICKY COM SELECTOR TO CHANGE
FREQUENCY.
Resolution: APPLIED POWER AIRCRAFT, CHECKED OPERATION OF NO.2 RADIO TUNING UNIT (RTU), SQUAWK
CONFIRMED, FOUND LINE SELECT KEY (1R) IS INTERMITTENT (STICKY) TO CHANGE FREQUENCY.
REMOVED RTU NO:2 P/N:822-0836-035 SIN: 267 FOR REPAIR. RECEIVED OK TO INSTALL AND INSTALLED
REPAIRED RTU NO:2 P/N:822-0836-035 SIN: 267 IN ACCORDANCE WITH GIV CMP 232336. RECEIVED UNIT
FROM ROCKWELL COLLINS REFERENCE 8130-3 WITH FORM TRACKING NO: 105121875 WORK ORDER:
WEP016-01211 CERT: ED7Y210Y DATED 16MAR2016. PERFORMED VIIF COMMUNICATIONS SYSTEM -
OPERATIONAL CHECK IN ACCORDANCE WITH GIV AMM 23-01-00,MARKER BEACON SYSTEM -
OPERATIONAL CHECK IN ACCORDANCE WITH GIV AMM 34-02-02, NAVIGATION / DISTANCE MEASURING
EQUIPMENT SYSTEMS - OPERATIONAL CHECK IN ACCORDANCE WITH GIV AMM 34-02-02, AUTOMATIC
DIRECTION FINDING SYSTEM - OPERATIONAL CHECK IN ACCORDANCE WITH GIV AMM 34-02-01
Billing Method Hours Rate Total
Labor USD: Time and Material ST 8.23 ® S132.00 $1,08636
Services USD: Time and Material S8,572.23
Total USD: 49,658.59
Services:
Ref. No. Description Quantity Sell Price USD Extended USD
For detail description of the work complied with see the Work Order Detail report.
Westficld_GAC_Work Unless otherwise indicated, all financial values listed in this document am in US Dollars (USD). Printed: 4(912016 4:26:50AM
Orderinvoice.rpt Page 3 of 14 LS MO
EFTA00652200
Bill To: HYPERION AIR, INC. WO #: SCI3577 Invoice Number: 6916001251
Services:
Ref. No. Description Quantity Sell Price USD Extended USD
6.2 #2 GAC REPAIRS 1.00 58,57223 58,572.23
Part Ref: 822-0836-035 RTU-4200 (RADIO TUNING UNIT)
62#1 GAC REPAIRS 1.00 50.00 S0.00
Step: 6.2.1 Completed APPLIED POWER AIRCRAFT, CHECKED OPERATION OF NO.2 RADIO
TUNING UNIT (RTU), SQUAWK CONFIRMED. FOUND LINE SELECT KEY
(1R) IS INTERMITTENT (STICKY) TO CHANGE FREQUENCY.
NEED TO REPLACED OR SEND FOR REPAIR RTU NO.2.
Discrepancy: 6.3 CUSTOMER REPORTS THE #2 IIF RADIO WILL NOT TUNE ("CP" AND "RT" LIGHT ILLUMINATES).
Resolution: GAINED ACCESS ON TAIL COMPARTMENT, VISUALLY INSPECTED THE IIF COUPLERS AND IIF
TRANSCEIVERS, FOUND THE RF COAX CONNECTOR ON IIF COUPLER NO.2 IS LOOSE. SECURED COAX
CONNECTOR ON IIF COUPLER NO.2.
PERFORMED HIGH FREQUENCY COMMUNICATION SYSTEMS NO. 1 AND NO.2 - OPERATIONAL TEST,
CHECKED GOOD ON BOTH SYTEM. RF RADIO CHECKS CONDUCTED WITH NY RADIO WITH TXJRX
QUALITY 4X4. WORK DONE IAW GULFSTREAM GIV MM ATA 23-03-00.
Billing Method Hours Rate Total
Labor USD: Time and Material ST 4.48 ® $132.00 559136
Total USD: 5591.36
Step: 6.3.1 Completed APPLIED POWER TO AIRCRAFT, PERFORMED HF NO. I AND NO.2 SYSTEM
OPERATIONAL TEST, FOUND NO.2 HF SYSTEM WITH "CP" LIGHT
ILLUMINATED AND WITH FAULT 08. ASKED CUSTOMER ABOUT THE HF
SQUAWK DUE TO HF SYSTEM NO. I IS THE ONE FAILED ON THE ITEM. PER
CUSTOMER. HE IS NOT SURE WHAT SYSTEM IS FAILING. GAIN ACCESS ON
TAIL COMPARTMENT, VISUALLY INSPECTED THE HF COUPLERS AND HF
TRANSCEIVERS, FOUND THE RF COAX CONNECTOR ON HF COUPLER NO.2
IS LOOSE. SECURED COAX CONNECTOR ON HF COUPLER NO.2.
PERFORMED HIGH FREQUENCY COMMUNICATION SYSTEMS NO. I AND
NO. 2 - OPERATIONAL TEST, CHECKED GOOD ON BOTH SYTEM. WORK
DONE IAW GULFSTREAM GIV MM ATA 23-03-00.
Step: 6.3.2 Completed USING 0-IS PSIG PRESSURE GAUGE, CHECKED THE PRESSURE IN BOTH NO.
1 AND NO.2 HF COUPLERS. NO. 1 COUPLER WAS AT 7 PSI AND NO. 2
COUPLER WAS AT APPX. 6.75 PSI. BOTH OF THESE READINGS ARE WITHIN
ALLOWABLE PRESSURES AS PER GIV A.M.M. 23-03-00, HIGH FREQUENCY
COMMUNICATION COUPLER - SERVICING.
Discrepancy: 6.4 CUSTOMER REPORTS THE FMS SELECTOR SWITCH NEEDS TO BE CHANGED (1/2 FMS SELECTOR
ON CENTER PEDESTAL).
Resolution: CONFIRMED CENTER FMS SELECTOR WILL ONLY BRIEFLY ILLUMINATE 1/2 FMS. REMOVED AND
CAPSULE AND REMOVED 4 EA. DEFECTIVE LAMPS P/N OL-3335, NO SERIAL NOS. REPLACED WITH 4 EA
NEW LAMPS P/N: 01.-3335 FROM GAC WESTFIELD STOCK. PERFORMED OPERATIONAL CHECK OF
SWITCHES IN ACCORDANCE WITH GIV AMM 33-01-00 ANNUNCIATOR LIGHT -OPERATIONAL TEST, WITH
NO DISCREPANCIES.
Billing Method Hours Rate Total
Labor USD: Time and Material ST 6.71 ® 5132.00 5885.72
Pans USD: Time and Material 5360.50
Total USD: 41,246.22
For detail description of the work complied with see the Work Order Detail report.
Westfield_GAC_Work Unless otherwise indicated, all financial values listed in this document am in US Dollars (USD). Printed: 49/2016 4:26:50AM
OrderInvoice.rpt Page 4 of 14 LS MO
EFTA00652201
Bill To: HYPERION AIR, INC. WO #: SC13577 Invoice Number: 6916001251
Parts:
Ref. No. Part number Description Quantity Sell price USD Extended USD
6.4 #1 OL3335 LAMP 4 $5.15 $20.60
6.1#2 99-212 SWITCH $339.90 $339.90
Step: 6.4.1 Completed GAINED ACCES TO THE FMS SELECTOR SWITCH (1/2 FMS) ON PEDESTAL.
REMOVED DEFECTIVE SWITCH (1/2 FMS) P/N: 99-212 FROM ASSEMBLY.
RECEIVED OK TO INSTALL AND INSTALLED A NEW SWITCH P/N: 99-212
THAT WAS RECEIVED FROM GAC-SAVANNAH WITH SHIPMENT NO.:
SASH316-34302, ENTERPRISE TRANSFER NO.: 000663760, DATED 03/08/2016 TO
THE (1/2 FMS) SWITCH POSITION ON ASSEMBLY. SECURED SWITCH
ASSEMBLY TO PEDESTAL WORK WAS DONE WITH REFERENCE TO THE
JET CENTER DRAWING NO. 08069100, TITLED NO. 3 FMS, DATED 3-11-88.
Step: 6.4.2 Completed PERFORMED OPERATIONAL CHECK IN ACCORDANCE WITH GIV AMM
33-01-00 ANNUNCIATOR LIGHTS - OPERATIONAL TEST, WITH NO
DISCREPANCIES.
Discrepancy: 6.5 CUSTOMER REQUESTS ASCB SWEEP
Resolution: PERFORMED ASCB BUS SWEEP IAW GIV 31-02-00. FOUND THAT THERE WERE NUMEROUS BUS
COUPLER CONNECTIONS THAT REQUIRED CLEANING (NOTICED SIGNAL FLUCTUATION ON
OSCILLOSCOPE). CLEANED BUS COUPLER CONNECTIONS AS REQUIRED AND SECURED ALL
CONNECTIONS. PERFORMED OPS CIIECK AND FINAL ASCB BUS SWEEP IN ACCORDANCE WITII GIV
AMM 31-02-00 AVIONICS STANDARD COMMUNICATION BUS - FAULT ISOLATION WITH NO
DISCREPANCIES.
Billing Method Hours Rate Total
Labor USD: Time and Material ST 13.00 ® $132.00 31,716.00
Total USD: 41,716.00
Step: 6.5.1 Completed PERFORMED ASCB BUS SWEEP 1AW GIV A.M.M. 31-02-00. FOUND THAT
THERE WERE NUMEROUS BUS COUPLER CONNECTIONS THAT REQUIRED
CLEANING (NOTICED SIGNAL FLUCTUATION ON OSCILLOSCOPE).
CLEANED BUS COUPLER CONNECTIONS AS REQUIRED AND SECURED ALL
CONNECTIONS. CHECKED ASCB BUS CHANNELS A AND B, FOUND GOOD AT
THIS TIME.
Discrepancy: 6.7 WHILE PERFORMING SPZ-8000 CND MAINTENANCE TEST NOTICED THAT TFIE LEFT FUEL LOW
LEVEL INDICATION STAYS WHITE IN ECIAS AND NO LIGHT ON STANDBY FUEL INDICATION WITII
ZERO FUEL ON WING.
Resolution: PERFORMED RESISTANCE CIIECK OF THE LEFT WING LOW LEVEL SENSOR AND FOUND TIIAT IT WAS
WITHIN LIMITS. WITH BOTH EICAS AND STANDBY FUEL QUANTITY INDICATOR SHOWING NO LOW
LEVEL WARNING, WITII ZERO FUEL ON TIIE LEFT WING. AT CONNECTOR 15A1P1, SWAPPED PINS C
(CLOSE DRY LEFT SIGNAL) WITII PIN D (CLOSE DRY RIGHT SIGNAL), AND THE PROBLEM FOLLOWED.
SWAPPED BOTII PINS BACK TO THEIR ORIGINAL POSITIONS. CONFIRMED BAD FUEL LOW LEVEL DUAL
CONTROL UNIT. REMOVED FUEL QUANTITY DUAL LOW LEVEL CONTROL UNIT PIN: 1159SCF215-33, SIN:
567 FROM THE AIRCRAFT. RECEIVED OK TO INSTALL AND INSTALLED A REPAIRED FUEL QUANTITY
DUAL LOW LEVEL CONTROL UNIT PIN: 1159SCF215-33,S/N: 690 THAT WAS RECEIVED FROM PARKER
HANNIFIN CORP., ELECTRONICS SYSTEMS DIV. WITII FAA 8130-3 FORM TRACKING NO.: 9E5210,
APPROVAL / CERTIFICATE NO.: FX1R156IC, DATED AUG/23/2010 TO THE AIRCRAFT. APPLIED POWER TO
TFIE AIRCRAFT AND FOUND THAT THE LEFT, RIGHT, AND TOTAL FUEL LEVEL INDICATION WAS AMBER
ON EICAS, ALSO THERE WAS LIGHT, (LEFT AND RIGHT) ON STANDBY FUEL INDICATOR. WORK WAS
DONE IAN' GIV CMP 284020, FUEL QUANTITY DUAL LOW LEVEL CONTROL UNIT - REMOVAL /
INSTALLATION. COMPLIED WITII GIV CMP 284029 FUEL LOW LEVEL WARNING SYSTEM - OPERAIONAL
TEST WITII NO DISCREPANCIES.
For detail description of the work complied with see the Work Order Detail report.
Westfield_GAC_Work Unless otherwise indicated, all financial values listed in this document am in US Dollars (USD). Printed: 4(912016 4:26:50AM
OrderInvoice.rpt Page 5 of 14 LS MO
EFTA00652202
Bill To: HYPERION AIR, INC. WO #: SCI3577 Invoice Number: 6916001251
Billing Method Hours Rate Total
Labor USD: Time and Material ST 12.98 ® $132.00 31,713.36
Pans USD: Time and Material $4,737.00
Total USD: $6,450.36
Pans:
Ref. No. Pan number: Description Quantity Sell price USD Extended USD
6.7 #1 1159SCF215-33 CONTROL UNIT. FUEL, LOW LEVEL 1 $4,737.00 $4,737.00
Step: 6.7.1 Completed PERFORMED RESISTANCE CHECK OF THE LEFT WING LOW LEVEL SENSOR
AND FOUND THAT IT WAS WITHIN LIMITS. WITH BOTH EICAS AND
STANDBY FUEL QUANTITY INDICATOR SHOWING NO LOW LEVEL
WARNING, WITH ZERO FUEL ON THE LEFT WING. AT CONNECTOR 15A1P1,
SWAPPED PINS C (CLOSE DRY LEFT SIGNAL) WITH PIN D (CLOSE. DRY
RIGHT SIGNAL), AND THE PROBLEM FOLLOWED. SWAPPED BOTH PINS
BACK TO THEIR ORIGINAL POSITIONS. CONFIRMED BAD FUEL LOW
LEVEL DUAL CONTROL UNIT. ALL WORK WAS DONE WITH REFERENCE
TO GIV A.M.M. 28-07-00.
Step: 6.7.2 Completed REMOVED FUEL QUANTITY DUAL LOW LEVEL CONTROL UNIT PIN:
1159SCF215-33, S/N: 567 FROM THE AIRCRAFT. RECEIVED OK TO INSTALL
AND INSTALLED A REPAIRED FUEL QUANTITY DUAL LOW LEVEL
CONTROL UNIT PEN: 1159SCF215-33, S/N: 690 THAT WAS RECEIVED FROM
PARKER HANNIFIN CORP., ELECTRONICS SYSTEMS DIV. WITH FAA 8130-3
FORM TRACKING NO.: 9E5210. APPROVAL / CERTIFICATE NO.: F7C1R156K,
DATED AUG/23/2010 TO THE AIRCRAFT. APPLIED POWER TO THE
AIRCRAFT AND FOUND THAT THE LEFT, RIGHT, AND TOTAL FUEL LEVEL
INDICATION WAS AMBER ON EICAS, ALSO THERE WAS LIGHT, (LEFT AND
RIGHT) ON STANDBY FUEL INDICATOR. WORK WAS DONE TAW G1V CMP
284020, FUEL QUANTITY DUAL LOW LEVEL CONTROL UNIT - REMOVAL /
INSTALLATION.
Step: 6.7.3 Completed COMPLIED WITH GIV CMP 284029 FUEL LOW LEVEL WARNING SYSTEM -
OPERAIONAL TEST WITH NO DISCREPANCIES.
Discrepancy: 6.8 DURING OW CMP GIV 541019 PYLON INTERNAL (LEFT) - INSPECTION FOUND PRECOOLER INLET
TEMPERATURE SENSOR CANNON PLUG TO HAVE BROKEN WIRE.
Resolution: REMOVED AND REPLACED CONNECTOR LEFT ENGINE PYLON TEMP SENSOR P/N 3153106F12S-35 NEW
FROM ELECTRO ENTERPRISES INC ., WITH CERTIFICATE OF CONFORMANCE, PACK SLIP NO. 1781911
DATED MAR 18, 2016. PERFORMED OPS CHECK WITH NO DISCREPANCIES. WORK DONE TAW WESTERN
COMMANDER , INC . WIRING DIAGRAM NO. 08030131 - BLEED AIR CONTROL MONITOR, DATED 2/10/89.
Billing Method Hours Rate Total
Labor USD: Time and Material ST 8.14 ® $132.00 $1,074.48
Pans USD: Time and Material $27.90
Total USD: $1,102.38
Pans:
Ref. No. Pan number Description Quantity Sell price USD Extended USD
6.8#1 NIS3106F12S-35 CONNECTOR 527.90 $27.90
For detail description of the work complied with see the Work Order Detail report.
Westficld_OAC_Work Unless otherwise indicated, all financial values listed in this document am in US Dollars (USD). Printed: 49/2016 4:26:50AM
OrderInvoice.rpt Page 6 of 14 LS MO
EFTA00652203
Bill To: HYPERION AIR, INC. WO #: SC13577 Invoice Number: 6916001251
Step: 6.8.1 Completed REMOVED AND REPLACED CONNECTOR LEFT ENGINE PYLON TEMP
SENSOR P/N MS3106F12S-35 NEW FROM ELECTRO ENTERPRISES INC.,
WITH CERTIFICATE OF CONFORMANCE, PACK SLIP NO. 1781911 DATED
MAR 18, 2016. WORK DONE JAW WESTERN COMMANDER , INC. WIRING
DIAGRAM NO. 08030131 - BLEED AIR CONTROL MONITOR, DATED 2/10189.
Step: 6.8.2 Completed PERFORMED OPS CHECK IN ACCORDANCE WITH WESTERN COMMANDER,
INC. WIRING DIAGRAM NO. 08030B1 - BLEED AIR CONTROL MONITOR.
DATED 2/10/89.
Discrepancy: 6.9 DURING AIRCRAFT POWER "ON", FOUND DC VOLTS ON ELECTRICAL POWER MONITOR TO READ
8.2 VOLTS WHEN SWITCH IS SET TO "AUX"
Resolution: APPLIED POWER TO AIRCRAFT AND OBSERVED 8.2 VOLTS DC DISPLAYED IN TILE POWER MONITOR
WITH AUX SELECTED. NOTED ALSO THAT IT WOULD ERRATICALLY JUMP FROM Si VOLTS TO 48.2
VOLTS TO 88.2 VOLTS AND BACK TO 8.2 VOLTS. WHEN SELECTING RADIO MASTER TO ON 28 VOLTS IS
DISPLAYED ON THE MONITOR WITH AUX SELECTED. CAN ALSO GET 28 VOLTS TO BE DISPLAYED BY
SELECTING THE PILOT, EICAS, AND COPILOT DISPLAYS TO ON. WHEN SELECTED BACK TO OFF, Si
VOLTS IS DISPLAYED ON TIIE MONITOR AGAIN. CHECKED DC ESS TEST POINT ON PILOT CIRCUIT
BREAKER PANEL AND READ 28 VOLTS WHILE POWER MONITOR STILL READ 8.2 VOLTS. ALL WORK
PERFORMED IN ACCORDANCE WITH GIV WIRING DIAGRAM MANUAL 24-30-00 DC POWER SUPPLY
SYSTEM. CUSTOMER HAS INDICATED TIIAT TIIIS IS A KNOWN ISSUE, AND THAT IT EXISTS IN NO
CONFIGURATION OTHER THAN AUX. CUSTOMER ELECTS NO FURTHER ACTION AT THIS TIME.
Billing Method Hours Rate Total
Labor USD: Time and Material ST 7.76 ® 5132.00 51,024.32
Total USD: 51,024.32
Step: 6.9.1 Completed APPLIED POWER TO AIRCRAFT AND OBSERVED 8.2 VOLTS DC DISPLAYED
IN THE POWER MONITOR WITH AUX SELECTED. NOTED ALSO THAT IT
WOULD ERRATICALLY JUMP FROM 8.2 VOLTS TO 48.2 VOLTS TO 88.2
VOLTS AND BACK TO 8.2 VOLTS. WHEN SELECTING RADIO MASTER TO ON
23 VOLTS IS DISPLAYED ON THE MONITOR WITH AUX SELECTED. CAN
ALSO GET 28 VOLTS TO BE DISPLAYED BY SELECTING THE PILOT, EICAS,
AND COPILOT DISPLAYS TO ON. WHEN SELECTED BACK TO OFF, 8.2
VOLTS IS DISPLAYED ON THE MONITOR AGAIN. AFTER POWER WAS ON
FOR ABOUT AN HOUR THE SAME 8.2 VOLT INDICATION COULD BE SEEN ON
THE POWER MONITOR BUT THIS TIME WITH EITHER AUX OR ESSENTIAL
SELECTED. CHECKED DC ESS TEST POINT ON PILOT CIRCUIT BREAKER
PANEL AND READ 28 VOLTS WHILE POWER MONITOR STILL READ 8.2
VOLTS. ALL WORK PERFORMED IN ACCORDANCE WITH GIV WIRING
DIAGRAM MANUAL 24-30-00 DC POWER SUPPLY SYSTEM.
Step: 6.9.2 Completed GAINED ACCESS TO CONNECTORS 318A1A5P2 AND 318A1A5P3 BY
REMOVING THE COCKPIT ENTRYWAY CENTER HEADLINER.
DISCONNECTED 318A1A5P2 AND BACKPINNED PIN "BB". APPLIED POWER
TO AIRCRAFT. WHILE MONITORING ELECTRICAL POWER MONITOR
PANEL -AUX PWR SW SELECTED, FOUND THAT DC VOLTAGE INDICATION
WOULD FLUCTUATE BETWEEN 8.2, 48.2, AND 88.2 VD( INTERMITTENTLY
WHILE INPUT VOLTAGE AT PINN BB OF CONNECTOR 318A1A5P2 PIN BB
SHOWS STEADY 14.7 VOLTS DC. CONNECTED 318A1A5P2. DISCONNECTED
318A1A5P3 AND BACKPINNED PIN "BB". APPLIED POWER TO AIRCRAFT.
WHILE MONITORING ELECTRICAL POWER MONITOR PANEL WITH ESS
PWR SW SELECTED, AGAIN FOUND THAT DC VOLTAGE INDICATION
WOULD FLUCTUATE BETWEEN 8.2.48.2. AND 88.2 VDC INTERMITTENTLY
WHILE THE INPUT VOLTAGE AT PIN ^BB^ OF CONNECTOR 318A1A5P3
SHOWS A STEADY VOLTAGE READING. SECURED CONNECTOR 318A1A5P3.
SECURED COCKPIT ENTRYWAY CENTER HEADLINER. CONFIRMED BAD
EPMP. WORK WAS DONE WITH REFERENCE TO GIV A.M.M. 24-02-00. DC
ELECTRICAL POWER - ELECTRICAL SCHEMATIC.
Discrepancy: 6.10 PILOTS WIPER MOTOR ONLY OPERATES AT LOW SPEED.
For detail description of the work complied with see the Work Order Detail report.
Westfield GAC Work Unless otherwise indicated, all financial values listed in this document am in US Dollars (USD). Printed: 4(912016 4:26:50AM
OrderInvoice.rpt Page 7 of 14 LS MO
EFTA00652204
Bill To: HYPERION AIR, INC. WO #: SCI3577 Invoice Number: 6916001251
Resolution: APPLIED POWER TO AIRCRAFT AND CHECKED FOR PROPER CONTROL VOLTAGE AT PILOT WIPER
CONTROL ASSEMBLY AND FOUND NO HALO VOLTAGE PRESENT. SWAPPED PILOT AND COPILOT WIPER
ON/OFF SWITCHES ON COP AND FOUND DISCREPANCY FOLLOWED SWITCH. RETURNED COPILOT
SWITCH BACK TO ITS ORIGINAL LOCATION. CONFIRMED PILOT WIPER ON/OFF SWITCH (P/N: 4271-503)
IS FAULTY. RECEIVED OK TO INSTALL. RECEIVED AND INSTALLED NEW WIPER ON/OFF SWITCH (P/N:
4271-503) FROM GAC SAVANNAH, REFERENCE 8130-3 DATED 16DEC2015, FORM TRACKING NUMBER:
20151216093100, APPROVAL / AUTHORIZATION NUMBER: ODA-511131-CE, INTO THE PILOT POSITION.
WORK PERFORMED IAA' GIV WDM 30-43-00. REFERENCE GULFSTREAM WESTFIELD WORK ORDER
SC13577.18.15 FOR SYSTEM OPS CHECK.
Billing Method Hours Rate Total
Labor USD: Time and Material ST 6.35 @ $132.00 511311.20
Pans USD: Time and Material 5694.90
Total USD: $1.53.3.10
Pans:
Ref. No. Part number: Description Quantity Sell price USD Extended USD
6.10#1 4271-503 SWITCH LIGHT ASSEMBLY I 5674.10 $674.10
6.10#2 D436-37 SLEEVE 10 51.42 514.20
6.10#3 D436-38 SLEEVE 4 51.65 $6.60
Step: 6.10.1 Completed APPLIED POWER TO AIRCRAFT AND CHECKED FOR PROPER CONTROL
VOLTAGE AT PILOT WIPER CONTROL ASSEMBLY AND FOUND NO HULO
VOLTAGE WAS PRESENT. SWAPPED PILOT AND COPILOT WIPER ON/OFF
SWITCHES ON COP AND FOUND DISCREPANCY FOLLOWED SWITCH.
RETURNED SWITCHES BACK TO THERE ORIGINAL LOCATIONS,
CONFIRMED PILOT WIPER ON/OFF SWITCH PIN 4271-503 IS FAULTY.
REFERENCED GIV WDM 30-43-00 FOR WORK PERFORMED.
Discrepancy: 6.11 DURING COCKPIT COMPARTMENT ABOVE FLOOR INSP CMP 532017 NOTED ON CO-PILOTS SIDE
CONSOLE AREA AFT END IS A BROKEN SWITCH LABLED ON/OFF.
Resolution: ACCOMPLISHED MINOR ALTERATION AND REMOVED DISCREPANT SWITCH P/N MTL-206N LABELED
COCKPIT LCD FROM COCKPIT SIDE CONSOLE AND BAGGED AND STOWED CONNECTOR AT SWITCH,
REFERENCE KC AVIATION DWG NO. GIV-31085-31-52. CAPPED AND STOWED WIRE "AS100CC20" AT
AIRSHOW C/B, REFERENCE KC AVIATION DWG NO. GIV-31085-31-52. DISCREPANT SWITCH WAS GIVEN
TO CUSTOMER FOR FURTHER EVALUATION AND REPAIR. INSTALLED A PLUG TO COVER REMAINING
HOLE DUE TO SWITCH REMOVAL. WEIGHT AND BALANCE CHANGE NEGLIGIBLE.
Billing Method Hours Rate Total
Labor USD: Time and Material ST 6.21 @ $132.00 58 19.72
Pans USD: Time and Material 55.16
Total USD: $824.88
Parts:
Ref. No. Part number. Description Quantity Sell price USD Extended USD
6.11 #1 AN525-10-7 SCREW 2 S2.58 $5.16
Item: 7 INTERIOR
For detail description of the work complied with see the Work Order Detail report.
Westficld_GAC_Work Unless otherwise indicated, all financial values listed in this document am in US Dollars (USD). Printed: 49/2016 4:26:50AM
Orderinvoice.rpt Page 8 of 14 LS MO
EFTA00652205
Bill To: HYPERION AIR, INC. WO #: SCI3577 Invoice Number 6916001251
Team Manager: Charles Heinle Part/Model 4:
Customer Coordinator: Vinny Cicala AC Serial No.fTail No.:
TSN/TSO:
CSN/CSO:
Aircraft Timc:
Discrepancy: 7.1 1 @ PROVIDE DOCUMENTATION OF REMOVED/REINSTALLED INTERIOR COMPONENTS ONLY.
Resolution: THE INTERIOR COMPONENTS REFERENCED IN TFIE R&D LOG (RDS 002) HAVE BEEN REMOVED AND
REINSTALLED USING GENERAL SHOP PRACTICES AND EXISTING HARDWARE. ANY COMPONENT
REQUIRING OPERATIONAL OR LEAK CHECK HAS BEEN CHECKED FOR NORMAL OPERATIONS WITH NO
DISCREPANCIES NOTED.
Discrepancy: 7.2 CUSTOMER REPORTS THE COPILOTS AIR VENT IS INOP AND BROKEN.
Resolution: PROVIDED ACCESS TO GASPER. FOUND AIRVENT BROKEN .INSTALLED NEW CUSTOMER SUPPLIED AIR
OUTLET P/N 1747-2. REFERENCE PART AND MATERIAL CERTIFICATION FORM , REFERENCE/SO# 726461
DATED 3/1412016 PERFORMED A OPERATIONAL CHECK OF GASPER . GASPER CHECK IS GOOD. NO
DEFECTS NOTED AT THIS TIME. REF. R/ D LOG FOR OPERATIONAL CHECK OF GASPER ON APU RUN .
Billing Method Hours Rate Total
Labor USD: Time and Material ST 9.77 (fr, $132.00 $1,289.64
Pans USD: Time and Material $1.56
Total USD: 41,291.20
Parts:
Ref. No. Part number: Description Quantity Sell price USD Extended USD
7.2#3 MS27039-0814 SCREW 2 50.78 $1.56
Step: 7.2.1 Completed FOUND AIRVENT BROKEN .ORDERED NEW AIR OUTLET P/N 1747-2 NSN ,
RECIEVED AND INSTALLED NEW AIR OUTLET P/N 1747-2. REFERENCE PART
OR MATERIAL CERTIFICATION FORM , REFERENCE/SO/I 726461 DATED
3/14/2016
Step: 7.2.2 Completed COPILOTS AIR VENT REQUIRES OPS CHECK DURING A/C RUNS.
Discrepancy: 73 CUSTOMER REPORTS THE CAPTAIN'S AIR-VENT IS BROKEN.
Resolution: PROVIDED ACCESS TO CAPTAINS GASPER. FOUND AIRVENT BROKEN. INSTALLED NEW CUSTOMERS
SUPPLIED GASPER AIR OUTLET P/N 1747-2. REFERENCE PART AND MATERIAL CERTIFICATION FORM ,
REFERENCE/SO# 726461 DATED 3/14/2016. PERFORMED A OPERATIONAL CHECK OF GASPER. GASPER
CHECK IS GOOD . NO DEFECTS NOTED AT THIS TIME. REF. R/ D LOG FOR OPERATIONAL CHECK OF
GASPER ON APU RUN .
Billing Method Hours Rate Total
Labor USD: Time and Material ST 7.93 @ $132.00 $1,046.76
Total USD: 41,046.76
For detail description of the work complied with see the Work Order Detail report.
Westfield_GAC_Work Unless otherwise indicated, all financial values listed in this document am in US Dollars (USD). Printed: 4/912016 4:26:50AM
OrderInvo
Entities
0 total entities mentioned
No entities found in this document
Document Metadata
- Document ID
- 37fb6791-d11c-4445-b872-d0f5ea102a5a
- Storage Key
- dataset_9/EFTA00652198.pdf
- Content Hash
- 70074c43c5766249bfc158c17c0f8958
- Created
- Feb 3, 2026