Your Refrigerated Air Experts
www.airprolneorporated.comi PROPOSAL
TO: DATE:
1212 1$
BRICE GORDON
JOB NAME:LOCATION:
Brice Cordon
JOB NUMBER: JOB PRONE:
Air Pro Inc. will provide labor and materials for the following work:
• Remove and dispose of the existing swamp cooler
• Cap and seal the existing swamp cooler supply duct with an insulated sheet metal cap
• Furnish and install one new Carrier 3.5 ton/16 SEER/single stage A/C split system with a new single stage/80%
AFUE furnace, furnace model #58DLA090-114, coil model #CNPVP4217ALA, condenser model
#24APB642A003
• Fabricate and install a new sheet metal transition to tie into the existing supply air plenum
• Fabricate and install a new filter rack stand to set the new coil and furnace on and tie into the existing return
air plenum
• Tie into the existing gas supply line with all new connections, including the addition of a sediment trap as
required by code
• Tie into the existing electrical for the furnace with all new connections, including hardwiring the furnace to a
switch as required by code
• Install a new digital programmable Carrier Edge thermostat
• Run all new double wall flue vent piping for the furnace to bring up to current code standards
• Set condenser on the patio/porch on the south side of the house
• Run line-set (refrigeration piping from the evaporator coil to the condenser through the exterior wall of the
mechanical closet and down to the condenser
• Run a gravity condensate line to the outdoors through the exterior wall of the mechanical closet
• Complete system check and start-up, including derating the furnace for altitude and setting R410A refrigerant
levels to the manufacturers specifications
• Permit fees and inspections
Sub Total $9,867.76
Tax $777.09
Total $10,644.85
Notes:
*Any/all high voltage electrical circuits for the new condenser is to be provided by others
*Skytrac lift for removing the swamp cooler is to be provided by others
*Condenser unit is to come equipped with a compressor sound blanket and condenser coil hail guards for unit
protection
EFTA01223580
We propose hereby to furnish material and labor-complete in accordance with the above specifications, for the sum
Dollars $10,644.85
Payment to be made as follows:
MATERIALS AND EQUIPMENT REMAIN PROPERTY OF AIR PRO, INC. UNTIL PAID FOR IN FULL.
All material is guaranteed to be as specified. All work to be completed in a professional manner according to standard practices. Any alteration or
deviation from above specifications involving extra costs will be executed only upon written orders and will become an extra charge over and above the
estimate. All agreements contingent upon strikes, accidents. or delays beyond our control. Owner to carry fire, tornado. and other necessary insurances.
Our workers are fully covered by Worker's Compensation insurance.
Authorized Signature:
Note: This proposal may be withdrawn by us if not accepted within days.
Acceptance of Proposal —The above prices, specifications, and
conditions are satisfactory and are hereby accepted. You are authorized to Signature:
do the work as specified. Payment will be made as outlined above.