attached is AD Winston comments on the link you sent us
do you envision this unit to supplement existing 7 tons hitting masterbedroom or want it to be standalone
i also have sandy berger (hanson contact) looking into this and hope to have 2 bids for your review
Richard Kahn
HBRK Associates Inc.
Begin forwarded message:
From: "M Palladino"
Subject: RE: 9 East 71st Street
Date: October 28, 2013 1:47:25 PM EDT
To: "Richard Kahn"
Cc: "Richard Barnett"
Gentlemen,
To start I have never installed or heard of thermo space, however I did look into
the link which was sent to me and I have a number of concerns.
The first is it utilizes refrigerant 22 which has been banned by the EPA and
discontinued in new equipment since January of 2010, its also an on/off system
not inverter driven, meaning once it reaches temperature the compressor shuts
off and does not come back on until temperature goes above set point. If this
system is to be installed, I would recommend an inverter driven system, which
allows the compressor to ramp up and down depending on the load conditions,
this works best because the system never shuts off avoiding the cold/hot spells
during the off cycle, not to mention it is much more energy efficient. I would
recommend installing a 3 ton Mitsubishi commercial grade inverter driven wall
mounted ductless split system which utilizes new R410A refrigerant, with
inverter driven technology.
Ductless split systems operate differently then a conventional system, which is
currently serving the entire house. They distribute colder air therefore
dehumidifying more then a conventional system can.. However this works much
better if the whole house was heated and cooled by a ductless split system.
Humidity seeks its own level and will find its way through doors, floors and
EFTA00974627
walls, therefore still finding its way into the master bedroom, because the
conventional system is still serving the majority of the house. We would no
longer have fresh air distributed into the bedroom, and we have no way to close
the return from the existing system, because it is a common return, unless we
opened up the ceiling in the master bedroom and physically capped and sealed
the return duct.
The installation on a system like this would be challenging, we would hang the
air-handler in the bedroom on the electrical closet wall, we would have to run
copper piping and insulation up to the roof where the condensing unit will be
placed via a rig. The roof and each floor would have to be drilled for refrigerant
and condensate piping. The majority of costs will be between the labor and
rigging.
In closing, I would only install a ductless split in this Residence for supplemental
heat/cool purposes only, not for quality of air or dehumidifying purposes
because of the reasons stated above. In this particular case supplemental does
not work, because ductless splits can only work down to a range of 61-63
degrees and the bedroom is currently capable of getting down to 58 degrees.
If you have any further questions or concerns please contact me anytime,
Michael Palladino
Vice President
A.D Winston Service Inc
Email:
From: Richard Kahn [mailto:
Sent: Monday, October 28, 2013 10:50 AM
To: Michael Palladino
Subject: 9 East 71st Street
Attached is link that Mr Epstein sent me
Richard Kahn
HBRK Associates Inc.
EFTA00974628
EFTA00974629
Entities
0 total entities mentioned
No entities found in this document
Document Metadata
- Document ID
- 193e79ef-446c-41f2-a5f1-0ab88137ee37
- Storage Key
- dataset_9/EFTA00974627.pdf
- Content Hash
- 9c0a93ad4348a2c4eda6df0b0098b12d
- Created
- Feb 3, 2026