Horizon Mechanical Systems Plumbing * Heating * Air Conditioning 18 Bullard Rd Moriarty, NM 87035 Lisc #86414 (505)832-0680 (505)463-2060 May 28, 2014 From: Duane Zachman To: Brice Gordon Subj: Whole House Protection from Electrical "Brownouts" and "Spikes" Brice, This is to summarize the information and budgets we have researched to find a solution to the problem that is occurring at the main house with electrical faults. These faults arc "Brownouts" and "Spikes" from the electric utility provider and cause equipment and electronics to be damaged. Since the problem is from the utility, we have explored options that protect the entire house electrical. Because the electrical service for the house is large and single phase, it makes equipment difficult to find availability and price. The following are 3 options we obtained information on. Option 1 - Two Voltage conditioners 240 volt, 200 KVA Estimated Price $103,000.00 Voltage Conditioners 2 x $28,000.00 = $56,000.00 Freight $ 2,000.00 Engineering $ 5,000.00 Wire, Conduit, Crane $10,000.00 Labor Installation $30,000.00 Option 2 — Two Voltage Regulators 240 Volt, 200 KVA Estimated Price $117,000.00 Voltage Regulators 2 x 35,000.00 = $70,000.00 Freight $ 2,000.00 Engineering $ 5,000.00 Wire, Conduit, Crane $10,000.00 Labor Installation $30,000.00 Option 5 - Two UPS 240 Volt, 200 KVA Estimated Price $450,000.00 UPS 2 x 200,000.00 = $400,000.00 Freight $ 2,000.00 Engineering $ 5,000.00 Wire, Conduit, Crane $10,000.00 Labor Installation $33,000.00 from a local Please note that these prices arc budget numbers and not a fixed quote. Pricing was obtained equipment. I hope this information is helpful. I am also attaching a brochure supplier in the research of this and a simple riser diagram to help explain this information. Thank You Duane Zachman EFTA01124543 "CO SWF.' r e's.•••rer" Modular Power AoPrr Conditioning s or System The Toughest Power Conditioner on theMarket Today .1fr" The Staco Energy Products Company Automatic Advantages: Voltage Regulator is based on a series regulation Modular construction for easy customization transformer controlled by variable transformers (Ws). It offers tight output regulation, robust design and Options offer more features and functionality easy customization. Extremely high overload/inrush rating In today's world, the cost of electrical power and its Very low cost of ownership due to efficiency and quality have become major operating concerns.The virtually maintenance-free operation continuing increase in the cost of electrical power Trouble-free operation with no active devices in power path has heightened interest in energy savings, and poor 1% or better output voltage regulation power quality has been identified as a cause of expensive malfunctions and shutdowns in new high Continuous voltage regulation—not crude step regulation technology equipment. Redundant manual regulation control Voltage regulation problems account for more than (raise/lower switch) 90% of the power problems seen at most sites. The Individual coil protection—avoid catastrophic cascade failures Staco Energy's base Automatic Voltage Regulator Gold plated contacts on all coils (AVR) provides protection against all but the most extreme voltage swings. When additional non-voltage Nickel plated copper bus bar issues occur, Staco Energy offers a series of options Easy, front panel access for service/installation that address such issues as high voltage transients, high harmonic content and site load balance. This No waveform distortion—no harmonics added integrated and targeted approach provides site- Small footprint specific power correction in a one-box solution. Able to withstand the continuous vibration of mobile applications Warranty The industry leading three-year warranty is our guarantee that Staco Energyoffers the toughest, most robust Voltage Regulation System on the market today. atE? EFTA01124544 Automatic Voltage Regulator The Staco Energy Automatic Voltage Regulator's unique construction blends precise regulation, high availability, and ruggedness into a highly customizable package. Base Regulator System Motorized Variable Transformer controlled, series regulation transformer Technology (buck-boost transformer with secondary wired In series with the load) kVA rating (single-phase) 2.5, 5, 7.5, 10, 15, 25. 37.5 (up to 500 kVA, contact factory) Voltage (single-phase) 120, 208, 230, 240, 277, 380, 400, 480 9, 15, 30, 45, 75, 112.5, 150, 225, 300, 400, 500 (up to 1,000 WA., WA rating (three-phase) contact factory.) Voltage (three-phase) 120, 208, 240, 380, 400, 420, 440, 480 Input Regulation (±1% output) +10% / -20% Input Regulation +10%1-25% (+1% -5% output) Response Time < 2 cycles 29 V/sec. at 480 Vac 3 phase, 48 V/sec. 240 Vac single phase. Correction Time Contact factory for other times. Efficiency Typical 97% for PLC units and 99% for AVR units Mean Time Between Failure Greater than 200,000 hours Harmonic Distortion None added Harmonic Content None added Overload Rating 33% - 2 hours 50%-1 hour 100% -15 minutes 1,000% - 30 cycles Output impedance Less than 1% (maintains tight regulation with 100% load step) Load Power Factor (pf) 0 lagging to 0 leading Attitude (operating) 10,000 feet without derating Temperature (operating) 0° to 40° C Heat Dissipation Voltage Regulator Typical 38 BTU/Fir/kVA; Power Conditioner Typical 95 BTU/Hr/kVA Audible Noise Less than 45 dBA Wiring Hardwired Enclosure NEMA 1 100% front accessible standard with NEMA 3R and others upon request. Power Conditioning Options Base Un' , P al r Optional 1 Power Problem Voltage . isolation Surge Advanced Individual " nsformer Protection MP Controller Phase Control Brownout X Under Volta / Sat X Over Volta / Su X H' h Volta,e Transient X ••htnin Protection X Unbalanced Load X 3rd Harmonic Reduction X Line Noise X Establish a Neutral on 0 •ut X Front Panel LCD Di a X Remote Communications & X Control • ut Re•utation *1% 5%) t1%(5%) t1%(5%) *0.5 Vac *0.5 Vac e rACO NfRGY EFTA01124545 Applications for Voltage Regulation Surge Protection General use surge suppressor designed for small service entrance panels or • BROADCAST: Regulation for broadcast individual equipment protection. Provides against high voltage transients transmitter sites and studios. generated both internally (such as motors, environmental control equipment, • COMMERCIAL High-rise building manufacturing, and office equipment) and externally (substation switching whole floor regulation or power transient, system faults, and severe weather such as lightning strikes). conditioning, input voltage regulation ■ 25 year free replacement warranty on surge protector for elevator control, large A/C chillers, ■ Parallel configuration provides 40kA (40,000 amps) per phase lighting, and other sensitive non-critical peak surge current protection systems. • Response time <= I nanosecond ■ INDUSTRIAL: Industrial automation, ■ Protection: all modes: L-N, L-L, N-G, L-G process control, CNC, factory robotics, ■ ANSV1EEE C62.41/62.45 Categories C, B and A with susceptibility up to medium facility level of point-of-use, heavy load exposure levels. Designed to protect against externally generated impulse machinery regulation. transients and internally generated switching/ring wave transients. ■ UL 1449 latest edition, CUL. UL 1283 listed • MARINE: Dockside or shipboard voltage regulation and power conditioning. Advanced Communications & Control (MP Controller) ■ MEDICAL: Medical Imaging: X-ray, ■ Increases output regulation to ± 0.5 Vac from standard ±1% CAT Scan, and MRI power conditioning; ■ LCD display with numeric/special function keypad building or whole floor regulation. ■ Monitor and manage output voltage and set points • MOBILE: Commercial broadcast and ■ Three form tecontact closures and eight logic level output signals military mobile communication trucks, IP Multiple set points may be programmed for variable speed, ramping, and trailers and shelters. dwell for dynamic voltage control ■ User programmed to accept peak-to-peak, average or RMS measurements Points to Consider ✓ Optional RS232 and RS422 communications for remote monitoring and control for Sizing and Configuration ■ MP controller standard on three-phase systems with Individual Phase Controlled (IPC) OUTPUT: Individual Phase Control Voltage? Vac Phase? Single Three Provides * 0.5 Vac regulation (w/MP Controller) on each phase, independently. Neutral Available? Yes No Provides load balancing for applications with unbalanced, single-phase loads or unbalanced and fluctuating utility power. Frequency? 50 Hz 60 Hz Double Shielded Isolation Transformer (Wye-Wye) • INPUT: ■ Provides extra protection & isolation between the utility and the load • Noise attenuation Voltage? No 120 dB common mode Neutral Required? Yes No ■ 60 dB transverse mode kVA Required No ci All copper construction — Traps 34 harmonic and triple harmonics Surge Suppression? Yes No a Removes electrical ground noise/interference Individual Phase Control? Yes No ■ Creates a bonded neutral (newly derived source) Advanced MP Controller? Yes No ■ 97% or greater efficiency Isolation Transformer? Yes No • Required where input & output voltages differ External Bypass? Yes No Additional Options Other? Yes No ■ Electrically and mechanically isolated external maintenance bypass in a free-standing or wall-mount cabinet ■ Input and output circuit breakers ■ Additional / custom power meters Custom enclosures for harsh /outdoor environments EFTA01124546 Circuit Diagrams Three Phase, Single Line Control Three Phase, Individual Line Control r v./SILL 111,1I•TCPWA POCULATOI rsayscamo About Staco Energy Products Since 1937, customers worldwide have been In addition to the Automatic Voltage Regulator we offer a wide array of relying on Stoco Energy Products Company power quality products, including: to deliver voltage control andpower quality • Unintemiptible Power Supplies solutions tailored to their needs. • Power Conditioners As a leading power quality resource, we offer • VoltageRegulators our customers world-doss support; from our • Power Factor Correction and thorough applications assessment, to our HarmonkMitigation ability to design and deliver a solution that is • Activeliamionk filters tailored to the specific needs ofour customers; • Variable Transformers through delivery and commissioning. • CustomEngineered TestSets Our professional, factory trained service team is in place to ensure that our customers'revenues are protected and their investment provides them with many years of trouble free operation. Sroco develops totalpower solutions for OEM and end user applications. Represented locally by: TACO Contact Us: US Toll Free: 866-261-1 igt Phone: 937-253-1191 CO ® E-mail: sales@stacoenetgy.com PA" EFTA01124547

Entities

0 total entities mentioned

No entities found in this document

Document Metadata

Document ID
06fd6d7a-f52b-407c-b8e4-c031cf687f1d
Storage Key
dataset_9/EFTA01124543.pdf
Content Hash
29c4b0e097aef9e970520ac8b3c78c69
Created
Feb 3, 2026