EFTA00602832.pdf
dataset_9 pdf 209.2 KB • Feb 3, 2026 • 3 pages
Corporate Headquarters
6855 Lyons Technology Circle • Suite 18
SLICK STEEL Toll Free Tel
C.nrnnia Creek • Fl • ttf171
CUSTOMER QUOTE
Name Kenneth Benjamin Jr. Tel 94410PPOlen Quote Date 05/18(2015
Company Jaredian Design Group Fax Valid Through 06/02/2015
Street TBD Email 8. 95....IMPRIMPOI" Project ID BS15229
City TBD Sales Rep Brian Buck
State ZZ Zip TBD
Country US Virgin Islands Page 1 of 3
Project Building 1
Location Street TBD City TBD County TBD
State ZZ Zip TBD Country US Virgin Islands
Engineering
Width 41%4" Code IBC 2009 Snow Gnd 0 Seismic Ss Shell Enclosed Occupancy Normal
Length 61%4" Wind Load 145 MPH Snow Roof 0 Seismic S1 Column Straight Thermal Unheated
Height 18'4720.4 Exposure C Snow Is 1.0 Seismic Co Base Deluxe Formed Trim Snow Exp Sheltered
3164'
Root Pitch .5:12 Live Load 20 Snow Ct 1.0 Frame Single Slope
Reducible Yes Snow Ce 1.0 Collateral 0.5
Left Endwall Spacing 2 @ 20' Type Post and Beam Bracing Cable Girt Bypass
Right Endwall Spacing 2 @ 20' Type Post and Beam Bracing Cable Girt Bypass
Front Sidewall Spacing 3 @ 20' Type NIA Bracing Portal Girt Bypass
Back Sidewall Spacing 3 @ 20' Type NIA Bracing Cable Girt Bypass
Root Panel Gauge 24 Style PBR Screw Type-Length Long Life.1 1/4° Color Not Specified
Wall Panel Gauge 24 Style PBR Screw Type-Length Long Life.1 1/4° Color Not Specified
Engineering EXPORT BUILDING with final destination of Virgin Islands via PORT Everglades with unloading and freight forwarding by others. Export
Notes package includes extra sheeting. nuts, bolts. fasteners. girts and purlins with all rollup doors specifically crated for export to provide additional
protection. It is the customer's responsibility to VERIFY All CODES & LOADS used to design this building as being in accordance vath local
requirements. Total weight is estimated as XX.XXX lbs. COD amount is to be paid in full 2 weeks prior to delivery to port.
Building Pricing
Oty Description
1 Base Building as per Engineering Specifications Included
1 Stamped Engineered Bulking Drawings (3 Sets) Included
1 Erecting Drawings (2 Sets) Included
1 Letter of Certification Included
Anchor Bolt Plans Included
1 All Frames Hot Dipped Galvanized. Secondary Members Pre-Galvanized Included
FSW 1053x64• Below BSW Grade Included
1 FSW, BSW, REW Open to 5*-6" Included
Full Trim Package Including: Corner Trim. Eave Trim. Sculptured Rake Trim Included
Die•formed Ridge Cap Included
Closure Strip Package Included
1 Gutters & Downspouts Included
2 Framed Opening Standard 12' x 16' For Rollup Doors Included
1 Personnel Door 30704 White Insulated Pre-Assembled Windlock Certified w/ Lever Handle w/ Threshold Included
2 Roll Up Steel Windlock Certified Non.Insulated w/ Chainhoist 12' x 16' Included
1 Roof Insulation 6"/ R19 WMP-VR w/ Starter Roll w/ Patch Tape Included
Wall Insulation 4"/ R13 WMP-VR w/ Starter Roll WI Patch Tape Included
1 Building & Accessory Freight To Port Everglades Included
I Export Package Including Extra Compnents and Special Crating Included
Florida Georgia Tennessee Website
Te
EFTA00602832
Corporate Headquarters
6855 Lyons Technology Circle • Suite 18
BUCK STEEL Toll Free Tel:
Coconut Creek • FL • 33073
CUSTOMER QUOTE
Name Kenneth Benjamin Jr. Tel Quote Date 05/18(2015
Company Jaredian Design Group Fax Valid Through 06/02(2015
Street TBD Email Project ID 8515229
City TBD Sales Rep Brian Buck
State ZZ Zip TBD
Country US Virgin Islands Page 2 of 3
Project Building 2
Location Street TBD City TBD County TBD
State ZZ Zip TBD Country US Virgin Islands
Engineering
Width 62' Code IBC 2009 Snow Gnd 0 Seismic Ss Shell Enclosed Occupancy Normal
Length 122' Wind Load 145 MPH Snow Roof 0 Seismic St Column Tapered Thermal Unheated
Height 12' Exposure C Snow is 1.0 Seismic Co Base Deluxe Formed Trim Snow Exp Sheltered
Root Pitch 1.5:12 Live Load 20 Snow Ct 1.0 Frame Gable Symmetrical
Reducible Yes Snow Ce 1.0 Collateral 0.5
Left Endwall Spacing 25723'6521t Type Post and Beam Bracing Cable Girt Bypass
Right Endwall Spacing 21'6523t/25' Type Post and Beam Bracing Cable Girt Bypass
Front Sidewall Spacing 2174420121' Type N/A Bracing Cable Girt Bypass
Back Sidewall Spacing 2174420121' Type N/A Bracing Cable Girt Bypass
Roof Panel Gauge 24 Style RROL Screw Type-Length Long Life-1 114• Color Not Specified
Wall Panel Gauge 24 Style PBR Screw Type-Length Long Life-1 114• Color Not Specified
Engineering
Notes
Building Pricing
Qty Description
Base Building as per Engineering Specifications Included
Stamped Engineered Bulking Drawings (3 Sets) Included
Erecting Drawings (2 Sets) Included
1 Letter of Codification Included
Anchor Bolt Plans Included
1 All Frames Hot-Dipped Galvanized. Secondary Members Pre-Galvanized Included
FSW 53164' Below BSW Grade Included
1 LEW. BSW Open to 5%6" For Block. REW Open to 2-4" For Block Included
5 Misc Steel Columns To Support Roof From Below Floor(Max 301b. per ft.. Bracing At Floor WiRdware Included
1 Mod-2 Design 40'. 20' Framelines #246 Included
Full Trim Package Including: Corner Trim. Eave Trim. Sculptured Rake Trim Included
1 Die-formed Ridge Cap Included
Closure Strip Package Included
1 Gutters & Downspouts Included
2 Framed Opening Standard 18'x 10' Rolling Steel Doors Included
1 Personnel Door 3070-M White Insulated Pre-Assembled Windlock Certified w/ Lever Handle w/ Threshold Included
2 Roll Up Windlock Certified Non-Insulated Chainhoist 18' x 10' Included
1 Roof Insulation 67 R19 WMP-VR w/ Starter Roll w/ Patch Tape Included
Wall Insulation 4"/ R13 WMP-VR wl Starter Roll ho Patch Tape Included
1 Building & Accessory Freight To Port Everglades Included
Export Package including Extra Compnents and Special Crating Included
Total Building
Webslte
EFTA00602833
Corporate Headquarters
6855 Lyons Technology Circle • Suite 18
SLICK STEEL Toll Free Te
Coconut Creek • FL • 33073
CUSTOMER QUOTE
Name Kenneth Benjamin Jr. Tel Quote Date 0511812015
Company Jaredian Design Group Fax Valid Through 06102/2015
Street TBD Email Project ID BS15229
City TBD Sales Rep Brian Buck
State ZZ Zip TBD
Country US Virgin Islands Page 3 of 3
Project Building Pricing
Oty Description
Base Building as per Engineering Specifications 126.640.00
Project Option Pricing (Options are NOT INCLUDED in the building price above)
Oty Description Unit Extended
Stamped Engineered Foundation Drawings (3 Sets) 5.250.00 5.250.00
1 Project Erecting Including Equipment Rental. Unloacing. and Labor(ESTIMATE) 36,000.00 36,000.00
IMPORTANT NOTES - PLEASE READ
• This quote is based on Buck Steers interpretation of plans and/or conversations with the customer. Buck Steel is NOT responsible for
any errors and/or ommissions.
• Carefully check this quote for completeness and verify the accuracy of the information contained within.
• This quote is valid through 6/2/2015. and is subject to review of pricing. Revisions to quote may result in a price adjustments
• Erecting is NOT included in this quote. unless specifically listed.
• Anchor bolts are NOT included in this quote and are NOT provided by Buck Steel.
• Concrete is NOT included in this quote and is NOT provided by Buck Steel
• Buck Steel and/or the Building Engineer is NOT the "Engineer of Record". The customer/owner is responsible for any "special building
inspector or "structural engineer required by the city or county for pre and post construction inspections.
• All prices are in USD.
• Pricing contained in this quote does not include any applicable sales taxes.
Website
EFTA00602834
Entities
0 total entities mentioned
No entities found in this document
Document Metadata
- Document ID
- 0256ea90-a39d-4ffa-ab36-f8b621e27814
- Storage Key
- dataset_9/EFTA00602832.pdf
- Content Hash
- 983ed26ccc29427a7aeff17f195abcf4
- Created
- Feb 3, 2026